F510 & F525 Ignition and Charging System – REMOVE AND INSTALL ARMATURE WITH COIL

1. Remove blower housing. (See Remove and Install Blower Housing in Section 20, Group 10.)
2. Disconnect wiring lead (A).
3. Remove cap screws (B) and armature with coil (C).
4. Loosely install armature with coil.
5. Connect wiring lead.
6. Adjust armature air gap. (See Adjust Armature Air Gap in this group.)
7. Install blower housing. (See Remove and Install Blower Housing in Section 20, Group 10.)