F510 & F525 – CHOKE PLATE CHECK

Reason:
To make sure the choke plate is fully closed when the throttle lever is in the full choke position.
Procedure:
IMPORTANT: Check and adjust throttle cable before adjusting choke, to ensure accurate choke adjustment.
1. Check and adjust throttle cable.
2. Move throttle control lever to full choke position.
3. Try to move choke rod (A) toward carburetor (in direction of arrow). Choke rod should NOT move. If choke rod moves in direction of arrow, the choke plate is not fully closed.
4. Move throttle lever to fast idle position.
5. Check holes (E) in control panel (F) and throttle arm (D). They MUST BE in visual alignment. Check for gap between screw (B) and choke arm (C). Gap should be approximately 0.25—3 mm (0.01—0.12 in.).
6. Try to move choke rod (A) toward control panel (arrow). Choke rod should NOT move. If choke rod moves in direction of arrow, the choke plate is not fully open.
Results:
• If choke rod DOES NOT move in either direction with throttle control lever in specific positions, choke operation is OK.
• If choke rod MOVES in either direction with throttle control lever in the specific positions, perform Choke Plate Adjustment procedure.

30. August 2021 by samuel07042012
Categories: F510-F525 | Leave a comment

Leave a Reply